AnsweredAAbutPierQ&A #1915412005-04-19 02:20 · Views 51

Drawing output error for vertical shear rebar in pi-shaped piers

파이형교각 수직전단철근 도면 출력에러검토부탁드립니다.

Answer

안녕하세요. 한길아이티입니다. 두부보 하면이 일직선으로 된 형태의 경우 HL1과 HL2값이 0이 되어야 합니다. 따라서, HL1을 0으로 입력하는 대신 CL1에 HL1만큼 더 해서 기둥의 위치를 조정하시면 됩니다. 감사합니다.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#191594About the drawing output settings .opt file492005-04-21
AnsweredAAbutPier#191587Error when printing the pier calculation report432005-04-21
AnsweredAAbutPier#191581Section check of abutment wing walls222005-04-21
AnsweredAAbutPier#191579When printing drawings262005-04-21
AnsweredAAbutPier#191578Question about analysis sections in seismic analysis302005-04-21
AnsweredAAbutPier#191580When checking piles...312005-04-20
AnsweredAAbutPier#191577Bearing seat rebar in skewed bridges232005-04-20
AnsweredAAbutPier#191575Error in quantity report (urgent review requested)222005-04-20
AnsweredAAbutPier#191576dimension202005-04-20
AnsweredAAbutPier#191566Load test182005-04-20
AnsweredAAbutPier#191556When generating a dxf file172005-04-19
AnsweredAAbutPier#191553Table handling for piers of the same type232005-04-19
AnsweredAAbutPier#191564Here is the title block file192005-04-19
AnsweredAAbutPier#191560Follow-up question about file 14128242005-04-19
AnsweredAAbutPier#191551The slope in bearing seat dimensions172005-04-19
AnsweredAAbutPier#191543Error when the wing wall angle to the slope line is 0 degrees242005-04-19
AnsweredAAbutPier#191541Drawing output error for vertical shear rebar in pi-shaped piers · Currently viewing512005-04-19
AnsweredAAbutPier#191531Wind load acting on live load942005-04-18
AnsweredAAbutPier#191539Seismic horizontal force for single-span bridges282005-04-18
AnsweredAAbutPier#191535EL values differ between AROAD and APIER572005-04-18
Sign in to ask