When checking foundation bearing capacity
교각(P2) 기초안정검토부분에서 지지력에 대한 안정검토에서 Qa값이 입력한값과 다르게 나옵니다. : 계산서 출력시에는 입력값이 출력되어집니다.
Answer
안녕하세요. 한길아이티입니다. 계산서 출력 및 [교각입력]-[단면도 제원]에서 확인한 바 이상이 없습니다. Qa값은 설계환경에서 입력한 "기초지반의 최대허용지지력"과 산식에 의해 계산된(보내주시 파일은 Hansen식 적용) 허용지지력 값중 작은 값이 적용이 됩니다. 다시 한 번 확인해 주시고 이상이 있으시면 게시판에 남기시거나 전화주시기 바랍니다. 감사합니다.
More in this list
| Status | Product | No. | Title | Views | Date |
|---|---|---|---|---|---|
| Answered | AAbutPier | #191311 | Add design environment feature for abutments and piers | 54 | 2005-04-06 |
| Answered | AAbutPier | #191310 | When entering bridge bearing loads | 34 | 2005-04-06 |
| Answered | AAbutPier | #191307 | When checking foundation bearing capacity · Currently viewing | 50 | 2005-04-05 |
| Answered | AAbutPier | #191306 | Error in seismic analysis | 57 | 2005-04-05 |
| Answered | AAbutPier | #191305 | During seismic analysis modeling | 48 | 2005-04-05 |
| Answered | AAbutPier | #191302 | Braking load calculation seems wrong | 40 | 2005-04-05 |
| Answered | AAbutPier | #191299 | Incorrect horizontal haunch rebar placement in abutment wing wall | 69 | 2005-04-04 |
| Answered | AAbutPier | #191300 | Please check | 34 | 2005-04-04 |
| Answered | AAbutPier | #191297 | Please review | 58 | 2005-04-02 |
| Answered | AAbutPier | #191296 | No load factor check for overload in class 2 and 3 bridge design | 96 | 2005-04-02 |
| Answered | AAbutPier | #191281 | When checking column tie bar arrangement design | 59 | 2005-04-02 |
| Answered | AAbutPier | #191278 | Program error after running SAP in pier calculation? | 52 | 2005-04-01 |
| Answered | AAbutPier | #191276 | Error in bearing seat dimension design check | 59 | 2005-04-01 |
| Answered | AAbutPier | #191270 | Please review internal error | 69 | 2005-04-01 |
| Answered | AAbutPier | #191288 | Punching shear | 185 | 2005-04-01 |
| Answered | AAbutPier | #191268 | Please review internal error | 52 | 2005-04-01 |
| Answered | AAbutPier | #191263 | Bridge bearing location error | 40 | 2005-04-01 |
| Answered | AAbutPier | #191257 | Cannot add rebar | 65 | 2005-03-31 |
| Answered | AAbutPier | #191254 | About sketches in general quantity calculation | 48 | 2005-03-31 |
| Answered | AAbutPier | #191259 | Please review seismic modeling error | 61 | 2005-03-31 |