Skip to content
AnsweredAAbutPierQ&A #1908312005-03-02 19:05 · Views 37

"Internal application error" in pier foundation reinforcement detailing

더이상 계산이 진전되지 않습니다. 그리고 심부구속철근계산에서 D19가 1개밖에 계산에 들어가지 않던데, (물론 N.G입니다) 제가 입력부분에서 어디를 잘못 넣은 것인지 모르겠읍니다. 연락 바랍니다. [개인정보] [개인정보]

Answer

안녕하세요. 한길아이티입니다. 1. 기초부배근은 확인한 바 이상이 없습니다. 다시 한번 확인해 주시기 바랍니다. 확인은 현재 패치로 하였습니다. 2. 심부구속철근은 원형인 경우 외측띠철근으로만 검토가 됩니다. 내측띠철근을 포함시키고자 하시는 경우은 [교각설계환경]-[설계선택사항]-"심부구속 띠철근 검토시 내측띠철근 적용"을 선택하시면 됩니다. 감사합니다.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#190856Please check seismic horizontal force values552005-03-04
AnsweredAAbutPier#190852About slab input222005-03-04
AnsweredAAbutPier#190843Mortar EL value when entering EL manually?272005-03-03
AnsweredAAbutPier#190842Question and error check request for pile calculation472005-03-03
AnsweredAAbutPier#190836When applying loads to the pier282005-03-03
AnsweredAAbutPier#190827Please check272005-03-03
AnsweredAAbutPier#190823Rebar reinforcement detailing check232005-03-03
AnsweredAAbutPier#190821About shear rebar in the pier foundation672005-03-02
AnsweredAAbutPier#190820Scaffolding quantity422005-03-02
AnsweredAAbutPier#190813Inquiry about collision load input152005-03-02
AnsweredAAbutPier#190831"Internal application error" in pier foundation reinforcement detailing · Currently viewing372005-03-02
AnsweredAAbutPier#190829Please check292005-03-02
AnsweredAAbutPier#190828Please check172005-03-02
AnsweredAAbutPier#190811Pier column tie bar arrangement342005-03-01
AnsweredAAbutPier#190810Bridge width differs between general drawing and quantity report212005-03-01
AnsweredAAbutPier#190808SAP launch error302005-03-01
AnsweredAAbutPier#190802Error generating the seismic analysis model252005-03-01
AnsweredAAbutPier#190794Coping beam shoe location222005-02-28
AnsweredAAbutPier#190804Error in stiffener design (item 6) when generating the calculation report272005-02-28
AnsweredAAbutPier#190793Pier reinforcement drawing is not drawn properly282005-02-28
Sign in to ask