Skip to content
AnsweredAAbutPierQ&A #1901032005-01-11 02:43 · Views 18

About seismic analysis

첨부된 파일을 보시면 시점부부터 교각으로 구성되어 종점부는 교대로 끝나면 접속교 형식입니다. 본교량에 접속되어 있어 시점부는 확폭이 되어 있고, 시점부 전면은 거더 2개, 후면은 거더 3개로 계획하였습니다. 내진해석 단면입력에 보시면 Span1이 이상하게 모델링 됩니다. 시점부 전면을 거더 3개와 확폭을 시키지 않으면 정상적으로 모델링 됩니다. 확인부탁드립니다.

Answer

안녕하세요. 한길아이티입니다. 시점위치가 교각인 경우 오류가 있어 수정하였습니다. 금일자 패치에 적용하도록 하겠습니다. 감사합니다.

Attachments on this post were deleted after the retention period (3 years after the last answer) and can no longer be downloaded. If you need the same material, please contact us.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#190104[Quantity] *** please check142005-01-11
AnsweredAAbutPier#190103About seismic analysis · Currently viewing182005-01-11
AnsweredAAbutPier#190097Please check182005-01-10
AnsweredAAbutPier#190105About seismic analysis172005-01-10
AnsweredAAbutPier#190094Question about abutment section input192005-01-10
AnsweredAAbutPier#190090Abutment edge distance check752005-01-09
AnsweredAAbutPier#190089Quantity calculation report output problem532005-01-08
AnsweredAAbutPier#190082Uploading file312005-01-08
AnsweredAAbutPier#190073Braking load calculation452005-01-08
AnsweredAAbutPier#190072Quantity calculation report1242005-01-07
AnsweredAAbutPier#190069Program crashes when printing pier (P4)332005-01-07
AnsweredAAbutPier#190077Longitudinal rib342005-01-07
AnsweredAAbutPier#190053Pier calculation report output error362005-01-06
AnsweredAAbutPier#190051PIER 3 structural calculation report won't output482005-01-06
AnsweredAAbutPier#190049sap /asolver won't run292005-01-06
AnsweredAAbutPier#190046Rigid body check and section check for spread footing thickness1262005-01-06
AnsweredAAbutPier#190058Wind load calculation1422005-01-06
AnsweredAAbutPier#190048Seismic analysis error282005-01-06
AnsweredAAbutPier#190041File recovery inquiry302005-01-06
AnsweredAAbutPier#190038Internal program error (seismic analysis section and cross beam)402005-01-06