Cannot modify abutment height
수고가 많으십니다. 종점측 교대를 12m에서 7m로 변경하려는데요 수정이 안되고 다운 됨니다. 확인부탁드려요.
Answer
안녕하세요. 한길아이티입니다. 교대높이를 조정하는 경우 WH2를 먼저 조정하신후에 WH1값을 조정하시면 됩니다. 조정되는 치수가 말씀하신 경우와 같이 큰 경우 배면쪽에서 (-)의 치수가 발생하는 경우가 있습니다. 즉 WH2를 조정하지 않고 WH1만 5m를 줄이는 경우 배면의 치수는 흉벽위치등에서 (-)가 발생하여 오류가 생깁니다. 배면을 먼저 조정하신 후에 전면의 치수를 조정하시기 바랍니다. 감사합니다.
More in this list
| Status | Product | No. | Title | Views | Date |
|---|---|---|---|---|---|
| Answered | AAbutPier | #189685 | Curved treatment at bottom of pier cap | 12 | 2004-12-14 |
| Answered | AAbutPier | #189678 | Cannot modify abutment height · Currently viewing | 19 | 2004-12-14 |
| Answered | AAbutPier | #189694 | Shear check of abutment front face | 52 | 2004-12-14 |
| Answered | AAbutPier | #189691 | About setting shoe direction | 29 | 2004-12-14 |
| Answered | AAbutPier | #189682 | Abutment shear force calculation | 17 | 2004-12-14 |
| Answered | AAbutPier | #189680 | Structural calculation report error | 23 | 2004-12-14 |
| Answered | AAbutPier | #189675 | Error when placing ties in P2 column | 24 | 2004-12-14 |
| Answered | AAbutPier | #189673 | Drawing generation error | 19 | 2004-12-14 |
| Answered | AAbutPier | #189666 | Please check automatic girder placement | 19 | 2004-12-14 |
| Answered | AAbutPier | #189664 | Quantity calculation report error | 10 | 2004-12-14 |
| Answered | AAbutPier | #189674 | About layers | 24 | 2004-12-13 |
| Answered | AAbutPier | #189658 | [Personal info] Please check | 30 | 2004-12-13 |
| Answered | AAbutPier | #189654 | Question about general quantities | 23 | 2004-12-13 |
| Answered | AAbutPier | #189668 | Applying individual footings to a pi-shaped pier | 20 | 2004-12-13 |
| Answered | AAbutPier | #189662 | Here is the drawing you requested | 17 | 2004-12-13 |
| Answered | AAbutPier | #189651 | About bridge bearings | 45 | 2004-12-13 |
| Answered | AAbutPier | #189645 | Question on bearing underside reinforcement calculation | 20 | 2004-12-11 |
| Answered | AAbutPier | #189641 | Shear force check | 21 | 2004-12-11 |
| Answered | AAbutPier | #189639 | Please check abutment wall height | 20 | 2004-12-10 |
| Answered | AAbutPier | #189642 | [HanGil contact] To the deputy manager: about coping | 27 | 2004-12-10 |