Correction request
*철근비검토에서 기호가 통일이 안되어있습니다. * 철근비 검토 ρmin : 14 / fy = 0.00467 0.80 √fck / fy = 0.00413 , ρmin = 0.00467 적용 ρmax = 0.75 x ρb = 0.75 x k1 x Φx (fck / fy) x {6000 / (6000 + fy)} = 0.02890 ρuse = As / bd = 0.00194 Pmax ≥ Puse, As ≥ As(req) x 4/3 → 철근비 만족, ∴ O.K (콘.설 6.3.2) Pmax ≥ Puse ----> ρmax ≥ ρuse
Answer
안녕하세요. 한길아이티입니다. 수정하여 금일자 패치에 적용하도록 하겠습니다. 감사합니다.
More in this list
| Status | Product | No. | Title | Views | Date |
|---|---|---|---|---|---|
| Answered | AAbutPier | #189229 | Internal error message after changing pier length | 12 | 2004-11-20 |
| Answered | AAbutPier | #189228 | Reinforcement drawing is not generated | 21 | 2004-11-20 |
| Answered | AAbutPier | #189226 | Parallel wing wall calculation report error | 31 | 2004-11-19 |
| Answered | AAbutPier | #189223 | Some suggestions for abutment reinforcement drawing | 24 | 2004-11-19 |
| Answered | AAbutPier | #189219 | Cannot proceed after modeling analysis | 8 | 2004-11-19 |
| Answered | AAbutPier | #189234 | Question | 10 | 2004-11-19 |
| Answered | AAbutPier | #189227 | Parapet rebar error | 10 | 2004-11-19 |
| Answered | AAbutPier | #189216 | About front-wall type wing walls | 5 | 2004-11-19 |
| Answered | AAbutPier | #189214 | Error entering bearing seat dimensions | 9 | 2004-11-19 |
| Answered | AAbutPier | #189202 | Earthwork quantity report output error | 6 | 2004-11-18 |
| Answered | AAbutPier | #189206 | Number of tie bars at top of pier 1 | 14 | 2004-11-18 |
| Answered | AAbutPier | #189205 | Generating APier seismic input file using brx | 16 | 2004-11-18 |
| Answered | AAbutPier | #189203 | Positive moment section design for pier cap inner span and support | 6 | 2004-11-18 |
| Answered | AAbutPier | #189198 | Correction request · Currently viewing | 15 | 2004-11-18 |
| Answered | AAbutPier | #189185 | Inquiry about bearing seat | 12 | 2004-11-18 |
| Answered | AAbutPier | #189182 | Considering water pressure on pier | 18 | 2004-11-18 |
| Answered | AAbutPier | #189195 | About sketches in quantity calculation - 1 | 34 | 2004-11-17 |
| Answered | AAbutPier | #189194 | Please review (please call) | 20 | 2004-11-17 |
| Answered | AAbutPier | #189193 | Please review (please call) | 16 | 2004-11-17 |
| Answered | AAbutPier | #189188 | Wing wall reinforcement drawing error for front-wall type | 14 | 2004-11-17 |