교대주철근입력에서 설계검토를 했을때 기초앞굽과 뒤굽의 모멘트가 큰데 어디가 잘못된지 모르겠읍니다. 교대1에서만 잘못나오는데 어디가 잘못된지 잘모르겠읍니다.. 검토바랍니다. 그럼 수고하십쇼.. p.s. 작업중인 화일을 올립니다..
Answer
안녕하세요. 한길아이티입니다. [교대입력]-[기초부설정]에서 bN값과 eN값의 입력이 누락되어 있습니다. (말뚝머리와 선단의 평균N값) 모두 "0"으로 입력되어 잘못된 말뚝반력이 계산되어 부재력값도 잘못 산정되고있습니다. 입력을 수정하신후 확인하시면 이상이 없습니다. 감사합니다.
More in this list
| Status | Product | No. | Title | Views | Date |
|---|---|---|---|---|---|
| Answered | AAbutPier | #188186 | Abutment | 16 | 2004-10-01 |
| Answered | AAbutPier | #188183 | Please review | 11 | 2004-10-01 |
| Answered | AAbutPier | #188181 | Question on abutment foundation reinforcement input | 8 | 2004-10-01 |
| Answered | AAbutPier | #188180 | Seismic analysis section input problem on brx import | 7 | 2004-10-01 |
| Answered | AAbutPier | #188165 | Applying top rebar splices | 23 | 2004-09-25 |
| Answered | AAbutPier | #188160 | In the wing wall drawing... | 5 | 2004-09-24 |
| Answered | AAbutPier | #188159 | DOWEL BAR error when parallel wing wall angle is 90 degrees | 29 | 2004-09-24 |
| Answered | AAbutPier | #188154 | Steel box section input problem | 17 | 2004-09-24 |
| Answered | AAbutPier | #188156 | Additional superstructure data required | 7 | 2004-09-24 |
| Answered | AAbutPier | #188150 | Please check the application height of wind load on live load at the pier | 14 | 2004-09-24 |
| Answered | AAbutPier | #188141 | Inquiry about dxf -> dwg conversion error | 7 | 2004-09-24 |
| Answered | AAbutPier | #188140 | About tie rebar... | 6 | 2004-09-23 |
| Answered | AAbutPier | #188138 | Error? · Currently viewing | 8 | 2004-09-23 |
| Answered | AAbutPier | #188151 | Problems in drawings and calculations | 12 | 2004-09-23 |
| Answered | AAbutPier | #188135 | Elastic and plastic design of columns | 13 | 2004-09-23 |
| Answered | AAbutPier | #188134 | cad file open error | 10 | 2004-09-23 |
| Answered | AAbutPier | #188133 | Dimension line problem in pier general drawing | 10 | 2004-09-23 |
| Answered | AAbutPier | #188131 | Pier input DATA field looks wrong | 10 | 2004-09-23 |
| Answered | AAbutPier | #188132 | Up-down PSC beam continuous bridge (continuous girders) | 32 | 2004-09-22 |
| Answered | AAbutPier | #188127 | Step cannot be applied to mass concrete | 13 | 2004-09-22 |