Step cannot be applied to mass concrete
이번에 패치하고 나서 mass콘크리트 단차적용이 안됩니다..
Answer
안녕하세요. 한길아이티입니다. MASS기초의 입력은 [일반입력]-[설계교대입력]에서 기초형태를 MASS로 설정하여야 합니다. 현재의 입력은 직접기초로 선택하여 버림콘크리트의 값을 키운 것입니다. 그리고 설계선택사항에서 MASS의 방향을 교축직각방향으로 선택하였으므로 정면도제원에서 입력하시면 됩니다. (기초형식 변경후) 감사합니다.
More in this list
| Status | Product | No. | Title | Views | Date |
|---|---|---|---|---|---|
| Answered | AAbutPier | #188186 | Abutment | 16 | 2004-10-01 |
| Answered | AAbutPier | #188183 | Please review | 11 | 2004-10-01 |
| Answered | AAbutPier | #188181 | Question on abutment foundation reinforcement input | 8 | 2004-10-01 |
| Answered | AAbutPier | #188180 | Seismic analysis section input problem on brx import | 7 | 2004-10-01 |
| Answered | AAbutPier | #188165 | Applying top rebar splices | 23 | 2004-09-25 |
| Answered | AAbutPier | #188160 | In the wing wall drawing... | 5 | 2004-09-24 |
| Answered | AAbutPier | #188159 | DOWEL BAR error when parallel wing wall angle is 90 degrees | 29 | 2004-09-24 |
| Answered | AAbutPier | #188154 | Steel box section input problem | 17 | 2004-09-24 |
| Answered | AAbutPier | #188156 | Additional superstructure data required | 7 | 2004-09-24 |
| Answered | AAbutPier | #188150 | Please check the application height of wind load on live load at the pier | 14 | 2004-09-24 |
| Answered | AAbutPier | #188141 | Inquiry about dxf -> dwg conversion error | 7 | 2004-09-24 |
| Answered | AAbutPier | #188140 | About tie rebar... | 6 | 2004-09-23 |
| Answered | AAbutPier | #188138 | Error? | 8 | 2004-09-23 |
| Answered | AAbutPier | #188151 | Problems in drawings and calculations | 12 | 2004-09-23 |
| Answered | AAbutPier | #188135 | Elastic and plastic design of columns | 13 | 2004-09-23 |
| Answered | AAbutPier | #188134 | cad file open error | 10 | 2004-09-23 |
| Answered | AAbutPier | #188133 | Dimension line problem in pier general drawing | 10 | 2004-09-23 |
| Answered | AAbutPier | #188131 | Pier input DATA field looks wrong | 10 | 2004-09-23 |
| Answered | AAbutPier | #188132 | Up-down PSC beam continuous bridge (continuous girders) | 32 | 2004-09-22 |
| Answered | AAbutPier | #188127 | Step cannot be applied to mass concrete · Currently viewing | 13 | 2004-09-22 |