현장타설말뚝 주철근 단면 변화 문의

안녕하십니까, 현장타설말뚝의 주철근 단면 변화 옵션 문의 드립니다. 현장타설 배근 옵션에서 주철근을 2단 배근하고 단면 변화구간을 적용하면 1단철근의 직경을 구분하여 적용이 됩니다. 주철근의 단면변화 적용을 위해서는 2단 철근 하단을 일부 삭제 해야되는데 변화구간이 2단에 적용이 안됩니다. 적용가능 옵션 문의드립니다. (단일현장타설말뚝과 상이하여 문의드립니다.) <img src="data:image/png;base64,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

첨부 그림

첨부 파일 1개 · 올린 분과 담당 직원만 볼 수 있습니다.

내 글이면 로그인

답변

안녕하세요. 한길아이티입니다. 기둥주철근 배근에 있어서는 각 단 별로 기둥의 특정위치에서 철근의 직경변경 또는 철근의 배근여부를 설정할 수 있도록 지원하고 있으며 단일현장타설말뚝인 경우도 기둥으로 배근되기에 동일하게 적용되고 있습니다. 다만 현장타설말뚝은 1단 주철근에 대해 철근의 직경변경은 지원하나 2,3단 철근을 적용한 경우 직경변경이나 철근의 배근여부를 설정할 수 있도록 지원하고 있지는 못합니다. 도움을 드리지 못하는 점 양해를 부탁드립니다. 감사합니다.

이 목록의 다른 글

상태제품번호제목조회날짜
답변 완료AAbutPier#2620743주형 단일현장타설말뚝 모멘트 최대위치 추가 질의262025-08-27
답변 완료AAbutPier#262072Skew에 따른 교대계획 적용 문의142025-08-27
답변 완료AAbutPier#262058교각 센터 이동 및 교대 가각부 가로보 받침 설치에 대한 문의312025-08-26
답변 완료AAbutPier#262009구조계산 질문272025-08-25
답변 완료AAbutPier#261958현장타설말뚝 주철근 단면 변화 문의 · 지금 보는 글532025-08-21
답변 완료AAbutPier#261955frame해석 지반정보 없음232025-08-21
답변 완료AAbutPier#261952코핑부 경사관련82025-08-21
답변 완료AAbutPier#261913STM 두부 주철근 인식관련 외402025-08-19
답변 완료AAbutPier#261932현장타설 말뚝 다발철근 배근 문의82025-08-19
답변 완료AAbutPier#261815교대입력에서 토압계수 산정시 수평지진계수 관련 질문입니다.332025-08-13
답변 완료AAbutPier#261708말뚝 응력검토 부분 궁금한게 있어서 여쭤봅니다.222025-08-06
답변 완료AAbutPier#261697내진해석 사용자 입력시292025-08-06
답변 완료AAbutPier#261676두부보 검토182025-08-05
답변 완료AAbutPier#261623도면 출력시 철근기호가 안나옵니다142025-08-01
답변 완료AAbutPier#261604날개벽 철근마킹 오류문의182025-07-31
답변 완료AAbutPier#261529내진해석 관련402025-07-29
답변 완료AAbutPier#261521두부보 배근 질문142025-07-28
답변 완료AAbutPier#261483선형방향 뒤틀림92025-07-25
답변 완료AAbutPier#261478단일현장타설말뚝 검토시 문의드립니다182025-07-24
답변 완료AAbutPier#261475사용자 수량 사용문의92025-07-24
로그인 후 문의