Field splice calculation

APlate로 작성된 성과물 검수중 현장이음에 관련하여 문의드립니다. [개인정보]에 제출된 소수주형교 성과물입니다. 현장이음에 적용된 단면력중 합성후 전단력 산정시 전단력이 음(-)일 경우 --> [합성후 고정하중] + [활하중] + [지점침하] 전단력이 양(+)일 경우 --> [합성후 고정하중] + [활하중]×2 + [지점침하] 전단력이 양일 경우 활하중의 2배를 취하는 근거는 무엇인지 질의합니다. 첨부 파일의 계산예 [개인정보] 합성후 전단력 : Sv = 1465.414 = [-500.253] + [-883.283] + [-81.877] [개인정보] 합성후 전단력 : Sv = 2439.197 = [ 588.658] + [ 908.932]×2 + [ 32.674]

Attached images 1Attached images 2
Answer

안녕하세요. 한길아이티입니다. 해당 부분만 2배할 규정은 없습니다. 일단 오류로 판단되는데요. 입력한 bri가 있어야 검토할 수 있을 것 같습니다. 수고하세요.

Attachments on this post were deleted after the retention period (3 years after the last answer) and can no longer be downloaded. If you need the same material, please contact us.

More in this list

StatusProductNo.TitleViewsDate
AnsweredACulvert#134522Calculation error in vertical earth pressure coefficient5692015-09-01
AnsweredARoad#134525Bolt count at top/bottom flange splices differs between drawing and report4482015-09-01
AnsweredAAbutPier#134523Error message during seismic analysis2962015-08-31
AnsweredARcBridge#134521Incorrect section forces at start/end in stability check4882015-08-31
Answered#134515Question about the waterway cross-section7342015-08-31
AnsweredACulvert#134508Question about moments at the bottom of left and right walls4482015-08-29
AnsweredAAbutPier#134504Allowable bearing capacity of cast-in-place piles2332015-08-28
AnsweredAAbutPier#134499Structural drawing and material table do not match4782015-08-28
AnsweredACulvert#134502Slab shear check2632015-08-28
Answered양배수장#134485Regarding discharge tank structural check4542015-08-27
AnsweredABeamDeck#134480Detailing of end reinforcement and distribution rebar5702015-08-27
AnsweredACulvert#134495Formula for determining required reinforcement in joint check2932015-08-27
AnsweredACulvert#134489How to add user-defined loads3002015-08-27
AnsweredACulvert#134470Maximum center spacing criteria in wall serviceability check3022015-08-27
AnsweredABeamDeck#134465Placement range of end reinforcement main rebar5422015-08-26
AnsweredACulvert#134464Program crashes when clicking load combination in input items2692015-08-26
AnsweredARoad#134463Manual editing of steel quantities3152015-08-26
Answered#134468Field splice calculation · Currently viewing5772015-08-26
AnsweredARoad#134462HanGil program won't launch5002015-08-26
AnsweredARoad#134459Pavement load3762015-08-26
Sign in to ask