Rainfall intensity does not change

1+343.50 지점의 강우강도 I가 변경되지 않습니다. 30년 기준으로 221.5mm/h 인데 166.9로 나옵니다. 새로 지점을 추가해서 만들어봐도 처음에는 221.5로 나왔다가 계산하는 과정에서 다시 166.9로 표기됩니다. 좀 급하게 필요하니 바로 부탁드립니다.

Follow-up2015-01-13 11:10

[개인정보]과 유선 통화 및 메일로 답변하였습니다. 30년 기준으로 I = 221.5mm/h은 Tc=5 분일때의 강우강도이고 166.9mm/h는 Tc=10 분일때의 강우강도입니다. 문의하시 암거는 Tc가 10분으로 계산되었기 때문에 강우강도가 166.9mm/h로 적용 된것입니다. 수고하세요.

More in this list

StatusProductNo.TitleViewsDate
AnsweredACulvert#131036Error importing MIDAS output (urgent)2492015-01-15
AnsweredARcBridge#131027Pile displacement in report appears incorrectly applied2532015-01-15
AnsweredACulvert#131023Invalid argument found2292015-01-15
AnsweredACulvert#131017Checking analysis results1862015-01-14
AnsweredAAbutPier#131015Seismic calculation report error2642015-01-14
AnsweredARcBridge#131030Rahmen foundation structural calculation2662015-01-14
AnsweredACulvert#131007Default rebar property error in reinforcement input1912015-01-14
AnsweredARoad#131004Member forces in section check differ from member force summary2612015-01-14
AnsweredACulvert#131006Can a sloped bottom slab be modeled?2222015-01-14
AnsweredACulvert#131009File error after STM analysis2102015-01-14
AnsweredACulvert#130997Request to convert .acl file to .acu9022015-01-14
AnsweredAAbutPier#130994Question about STM3072015-01-14
AnsweredACulvert#130991Questions on underpass design9242015-01-14
AnsweredACulvert#130982Both-side and unbalanced earth pressure applied twice in INPUT file when unbalanced pressure is not considered2532015-01-13
AnsweredACulvert#130976Modeling error when applying railway loads2562015-01-13
AnsweredACulvert#130967Request for a structural calculation report3332015-01-13
AnsweredACulvert#130990Inquiry2142015-01-13
AnsweredACulvert#130978Joint settings for U-type underpass2312015-01-13
AnsweredACulvert#130966Converting .acl files to .acu files2032015-01-13
Answered#130965Rainfall intensity does not change · Currently viewing3872015-01-12
Sign in to ask