Skip to content
AnsweredQ&A #1200122013-07-11 19:10 · Views 317

Question about the field splice calculation report output

현장이음부 계산서 출력에 대해 문의드립니다 거더가 4개소인데, 각 거더별로 현장이음 계산서를 출력하는 방법이 있는지 확인부탁드립니다

Answer

안녕하세요. 한길아이티입니다. 확인 결과 예측하신대로 1개 거더만 출력되고 있네요. 추후 전체출력 옵션 추가가 필요할 것 같네요. 감사합니다.

More in this list

StatusProductNo.TitleViewsDate
AnsweredACulvert#120065Shear reinforcement2042013-07-12
AnsweredARoad#120064Transverse load distribution results won't proceed to next tab1612013-07-12
AnsweredARoad#120052Program keeps crashing1542013-07-12
AnsweredARcBridge#120046Request for review6592013-07-12
AnsweredACulvert#120046Request for review6592013-07-12
AnsweredACulvert#120038Adding nodes to a section3082013-07-12
AnsweredACulvert#120062Input cell disappears when changing D value after footing skew layout recommendation2892013-07-12
AnsweredAAbutPier#120061Reference file for quantity takeoff2072013-07-12
AnsweredARcBridge#120049License dongle not recognized after installing new version1952013-07-12
AnsweredAAbutPier#120007Regarding pier foundation2132013-07-12
AnsweredARoad#120006MFC error and other issues1972013-07-12
AnsweredAWall#119997Inquiry4142013-07-12
AnsweredAAbutPier#119979Check of normal-condition horizontal force on bridge bearings3392013-07-11
AnsweredARcBridge#119970Please check 3D modeling error1632013-07-11
AnsweredARoad#120017Vertical stiffeners are not displayed2122013-07-11
Answered#120012Question about the field splice calculation report output · Currently viewing3172013-07-11
AnsweredARoad#120009Fatigue stress check1892013-07-11
AnsweredARoad#119972Generating cross beam calculation report1952013-07-11
AnsweredAAbutPier#119969Request regarding quantity takeoff3422013-07-11
AnsweredARoad#119968Tank trailer load on stringers1622013-07-11
Sign in to ask