AnsweredQ&A #1145762012-11-23 09:19 · Views 353
Culvert earthwork quantity calculation error
암거공 수량산출시에 평균터파기 산출 입력완료 후 토공수량산출에서 단위수량 및 집계표가 작성되지 않습니다. (4개소 중 3개소) 확인부탁드립니다.
Answer
안녕하세요 한길아이티 입니다. 문의하신 사항은 설정에 문제가 있었습니다. 1. 옵션 -> 배수공 -> 계산 -> 임의수정된 수량변경 선택 2. 자동계산 클릭 3. 공정의 암거공 선택후 프로젝트관리의 해당스테이선 더블클릭하면 " STATION 추가/ 수량 산출 정보입력창이 출현 합니다. 그럼 저장을 누르시면 수량산출이 출력되는걸 보실수 있습니다.
More in this list
| Status | Product | No. | Title | Views | Date |
|---|---|---|---|---|---|
| Answered | AAbutPier | #114636 | Question about tie bar reinforcement detailing | 220 | 2012-11-26 |
| Answered | AAbutPier | #114633 | NG appears in analysis results | 250 | 2012-11-26 |
| Answered | ABeamDeck | #114623 | Deck slab design check | 437 | 2012-11-26 |
| Answered | ACulvert | #114627 | Error during update; existing files won't open | 163 | 2012-11-26 |
| Answered | ARcBridge | #114622 | Structural calculation report error | 208 | 2012-11-24 |
| Answered | ACulvert | #114610 | File won't open after printing structural calculation report | 161 | 2012-11-24 |
| Answered | ACulvert | #114595 | Spring reactions and displacements under live load are all 0 with piles installed | 187 | 2012-11-23 |
| Answered | ACulvert | #114588 | Inquiry about rebar placement error | 218 | 2012-11-23 |
| Answered | AAbutPier | #114577 | Please review | 255 | 2012-11-23 |
| Answered | ACulvert | #114592 | Shrinkage and temperature rebar under railway design standards | 107 | 2012-11-23 |
| Answered | ARoad | #114591 | Top slab and webs | 165 | 2012-11-23 |
| Answered | #114576 | Culvert earthwork quantity calculation error · Currently viewing | 353 | 2012-11-23 | |
| Answered | AAbutPier | #114575 | Seismic horizontal force on substructure at movable end | 246 | 2012-11-23 |
| Answered | ACulvert | #114571 | Load combinations by load factor | 119 | 2012-11-23 |
| Answered | AAbutPier | #114563 | Coordinate and EL calculation | 219 | 2012-11-23 |
| Answered | ACulvert | #114561 | Rebar specification and quantity error | 234 | 2012-11-23 |
| Answered | ACulvert | #114558 | Rebar specification and quantity error | 193 | 2012-11-22 |
| Answered | ARoad | #114570 | Non-destructive testing | 178 | 2012-11-22 |
| Answered | AAbutPier | #114564 | Basis for non-destructive testing quantities? | 225 | 2012-11-22 |
| Answered | #114560 | Wrong freezing index after selecting weather station | 384 | 2012-11-22 |