AnsweredQ&A #873192010-08-03 09:49 · Views 544
Attachment
죄송합니다... 다시올려드립니다... 추가 질문으로 구조계산서 1번이 출력되질 않읍니다..
Answer
안녕하세요. 한길아이티입니다. 문의하신 가설하중 입력값에 대해 코드상에서 확인한 결과 "합성전 사하중-1" 항목의 "TMPSTCON"의 값이 들어가도록 되어 있습니다. 다만 지난번 작업하면서 계산서 3장의 부재력 집계표는 만들지 않았으므로 바로 값을 확인하시기는 어렵게 되어 있습니다. 수고하세요.
More in this list
| Status | Product | No. | Title | Views | Date |
|---|---|---|---|---|---|
| Answered | #87319 | Attachment · Currently viewing | 544 | 2010-08-03 | |
| Answered | AAbutPier | #87315 | Approach and buffer slabs | 737 | 2010-08-03 |
| Answered | AAbutPier | #87301 | Excel output error | 336 | 2010-08-03 |
| Answered | AAbutPier | #87292 | Question about user-defined loads | 292 | 2010-08-02 |
| Answered | AAbutPier | #87284 | Question | 412 | 2010-08-02 |
| Answered | ACulvert | #87285 | Approach slab section | 198 | 2010-08-02 |
| Answered | ACulvert | #87306 | Rebar display error | 194 | 2010-08-02 |
| Answered | ACulvert | #87281 | Main rebar input | 217 | 2010-08-02 |
| Answered | AAbutPier | #87278 | Converting a 2003 version file to the 2007 version | 283 | 2010-08-02 |
| Answered | AAbutPier | #87276 | Error importing integrated bridge data | 272 | 2010-08-02 |
| Answered | ARoad | #87276 | Error importing integrated bridge data | 272 | 2010-08-02 |
| Answered | AAbutPier | #87275 | Deliverable file issue, possibly due to version difference | 289 | 2010-08-02 |
| Answered | AWall | #87310 | Question about horizontal displacement | 379 | 2010-08-02 |
| Answered | #87308 | Section forces during temporary construction stage | 501 | 2010-08-02 | |
| Answered | #87304 | Question about installation | 592 | 2010-08-02 | |
| Answered | ACulvert | #87300 | Question about the analysis program | 207 | 2010-08-02 |
| Answered | AAbutPier | #87297 | Results following the user load answer below | 258 | 2010-08-02 |
| Answered | AWall | #87295 | Load calculation | 688 | 2010-08-02 |
| Answered | ACulvert | #87289 | License dongle is not recognized | 220 | 2010-08-02 |
| Answered | ACulvert | #87274 | Is pile foundation design not supported for retaining walls? | 220 | 2010-08-01 |