AnsweredQ&A #2498842009-11-27 16:58 · Views 480
Jack-up stiffeners at pier
교각부 잭업보강재 계산에서 보강재 사용열수를 1개소로 적용하였는데 2개소로 나오며 유효폭 산정부분에서 d값이 들어갑니다 교량받침을 기준으로 반대편 잭업보강재의 간격이 들어가네요 확인 부탁드려요
Answer
안녕하세요. 한길아이티입니다. 지적하신 부분은 수정했습니다 절점 번호 오류 및 체크리스트 값 차이도 수정했습니다. 수고하세요.
More in this list
| Status | Product | No. | Title | Views | Date |
|---|---|---|---|---|---|
| Answered | AAbutPier | #249905 | Error in seismic analysis | 182 | 2009-11-30 |
| Answered | #249903 | Structural calculation report chapter 4 | 477 | 2009-11-30 | |
| Answered | ACulvert | #249902 | Question about U-Type deliverables | 151 | 2009-11-30 |
| Answered | ATypeDesign | #249900 | Allowable bending stress error for support members | 436 | 2009-11-28 |
| Answered | AWall | #249895 | In connection with *** | 337 | 2009-11-28 |
| Answered | AAbutPier | #249887 | Abutment reinforcement error | 221 | 2009-11-28 |
| Answered | ARoad | #249885 | Question about structural calculation report checklist | 223 | 2009-11-28 |
| Answered | AAbutPier | #249883 | Seismic analysis model setup | 134 | 2009-11-28 |
| Answered | ABeamDeck | #249880 | Drawing output error | 265 | 2009-11-28 |
| Answered | AAbutPier | #249878 | About clearance under the bridge | 194 | 2009-11-28 |
| Answered | ABeamDeck | #249869 | Drawing output error | 315 | 2009-11-27 |
| Answered | AAbutPier | #249867 | Bearing seat check | 160 | 2009-11-27 |
| Answered | AAbutPier | #249866 | Are versions 2003 and 2007 incompatible? | 243 | 2009-11-27 |
| Answered | ARcBridge | #249864 | Cannot proceed to next step from bridge dimensions | 246 | 2009-11-27 |
| Answered | AAbutPier | #249899 | Please check | 188 | 2009-11-27 |
| Answered | AAbutPier | #249896 | Values do not match | 169 | 2009-11-27 |
| Answered | ACulvert | #249889 | Live load application error for culvert with anti-flotation key | 153 | 2009-11-27 |
| Answered | #249884 | Jack-up stiffeners at pier · Currently viewing | 480 | 2009-11-27 | |
| Answered | AAbutPier | #249868 | Horizontal rebar in approach slab | 226 | 2009-11-27 |
| Answered | AAbutPier | #249862 | Shear rebar spacing limit | 302 | 2009-11-27 |