Skip to content
AnsweredQ&A #2495472009-11-23 09:58 · Views 414

Please review

안녕하십니까. 지난번 전화로 말씀드린 내용처럼 sap데이타를 수정하여 aplate에서 불려들였습니다. 그런데 불려들여온 단면력 값이 sap 데이타와 aplate 계산서 값이 틀립니다.(가로보 부분 검토시) 검토부탁드립니다.

Answer

안녕하세요. 한길아이티입니다. 현재 가로보 코드에서 합성전 : 합성전-1 Steel + 합성전-2 Concrete 이것으로 되어 있습니다. 함 확인해 주세요.

More in this list

StatusProductNo.TitleViewsDate
AnsweredABeamDeck#249561Live load deflection2802009-11-23
AnsweredACulvert#249556Negative moment at outer wall midspan looks wrong2122009-11-23
AnsweredARcBridge#249553Please check direction notation in manhole drawing output1982009-11-23
AnsweredAAbutPier#249550No answer received for post ***1372009-11-23
AnsweredAAbutPier#249542File keeps causing errors1042009-11-23
AnsweredAWall#249537Please review3552009-11-23
AnsweredAAbutPier#249566Please also review question no. *** (no content)892009-11-23
AnsweredATypeDesign#249562Follow-up to the question below4192009-11-23
Answered#249560Horizontal bracing5132009-11-23
AnsweredACulvert#249555Active earth pressure coefficient3332009-11-23
AnsweredAAbutPier#249554Basis for applied moment in wall design2152009-11-23
AnsweredAAbutPier#249549Impact factor error in parapet wall section force calculation2542009-11-23
Answered#249547Please review · Currently viewing4142009-11-23
AnsweredAAbutPier#249545Section force error from footing self-weight in section design1532009-11-23
AnsweredAAbutPier#249544About post ***1702009-11-23
AnsweredAAbutPier#249535CAD file is not generated1862009-11-23
AnsweredRcGhost#249536RcGhost section check error5582009-11-22
AnsweredAWall#249531Rebar placed misaligned with structure outline2842009-11-21
Answered#249533Camber diagram output5432009-11-21
AnsweredAWall#249532How to output the full quantity calculation report and error when printing2522009-11-21