Skip to content
AnsweredQ&A #2491782009-11-13 17:37 · Views 461

Inquiry about stiffeners

아래 답변대로 변경후 작업을 하엿지만, 출력시 보강재가 입력되지 않은것 같습니다 답변부탁드립니다

Answer

안녕하세요. 한길아이티입니다. 오류 부분 수정했습니다. 자동업그레이드 후 확인해 주세요. 수고하세요.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#249192Modeling error in seismic analysis2472009-11-16
AnsweredARcBridge#249191Spacer rebar application error and wing wall check request3892009-11-15
AnsweredAAbutPier#249185Reposting in case you missed it1252009-11-14
AnsweredAWall#249171Counterfort retaining wall4042009-11-14
AnsweredARoad#249174Cross beam slope2562009-11-14
AnsweredAAbutPier#249169Additional abutment length1672009-11-14
AnsweredARoad#249167Error in structural calculation report output for empirical design2162009-11-14
AnsweredAAbutPier#249157Error when arranging pier drawings2392009-11-13
AnsweredAAbutPier#249154Diagonal reinforcement is not displayed2142009-11-13
AnsweredACulvert#249153Main rebar spacing of exterior wall2192009-11-13
AnsweredARoad#249142About field splice design1582009-11-13
AnsweredACulvert#249184Question about pile reaction calculation2962009-11-13
Answered#249178Inquiry about stiffeners · Currently viewing4612009-11-13
Answered#249173Inquiry about the checklist and section summary drawing4272009-11-13
AnsweredAAbutPier#249170How are section forces transformed when the pier foundation is rotated?1572009-11-13
AnsweredACulvert#249159Additional request following the question below1572009-11-13
AnsweredAAbutPier#249149Please check1602009-11-13
AnsweredAAbutPier#249143One more request1672009-11-13
AnsweredAAbutPier#249140Please check the warning message2032009-11-13
AnsweredAAbutPier#249139Support request2332009-11-13
Sign in to ask